Permit: T04CM01859

Parcel: 133220210

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/09/2005 FRAMING Approved IVRS - Inspection :*
01/04/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHOWER NOT COMPLETE
2) PLASTIC FEMALE FITTINGS NOT ALLOWED WITH METAL MALE FITTINGS AT SHOWER
3) DBL LAV NOT PLUMBED OR VENTED
4) BALL VALVES CANNOT BE ENCLOSED IN WALL WITHOUT ACCESS PANEL
6) CLIP TRUSS NORTH END TO BEARING WALL WITH H2.5 CLIPS
7) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES
8) ANCHOR BOLTS REQUIRED WITHIN 12" OF BOTTOM PLATE SPLICES
9) SMOKE DETECTOR REQUIRED WITHIN 12" OF BEDROOM CEILING AND IN HALL
10) CLIP TRUSSES AT MID POINT BEARING
11) WATER HEATER "B" VENT NOT INSTALLED
11/01/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) NEED STUCCO MESH COMPLETED BEFORE INTERMEDIATES
10/28/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) INTERMEDIATE INSPECTIONS ARE NOT PERFORMED UNTIL THE STUCCO MESH IS COMPLETE
09/17/2004 FRAMING Not ready for Inspection IVRS - Inspection :*