Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM01852
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/15/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
09/13/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO FUSES IN A/C DISCONNECT BOXES ( EAST AND WEST) 2) PROVIDE PROPER ACCESS CLEARANCE TO A/C DISCONNECT AROUND EXTERIOR COMPONENT ON WEST SIDE 3) CORRECT DIFFERENT GAUGE GROUND WIRES DBL TAPPED IN PANEL 4) PANEL SPECS DO NOT PROVIDE FOR DBLE TAPPING NEUTRALS 5) NEED 2ND SCREW FOR PANEL DEAD FRONT 6) FURNACE INSTALL NOT COMPLETE 7) RAISE DISHWASHER DRAIN TO COUNTER BOTTOM |