Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01852
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/14/2004 | FRAMING | Approved | IVRS - Inspection :* | |
07/13/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HEADERS TO BEAR DIRECTLY ON STUDS AND STUDS TO PLATES 2) INSTALL POSITIVE PORCH BEAM TO ? TO POST CONNECTION 3) RE-INSTALL FIRE BLOCKS KNOCKED OUT BY TRADES 4) STRAP ACROSS NOT CONTINOUS STUDS ALL BEARING WALLS 5) INSTALL A35'S AND NAILS ALL LEDGES TO STUDS 6) STRAP ALL BEAMS AT BEARING 7) REPLACE EXCESSIVELY NOTCHED STUDS 7) COMPLETE LATH 8) STOPPED INSPECTION 9) COMPLETE ALL TRADES AND RECALL |
|
07/12/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) PLUMBING INCOMPLETE-SUBS STILL WORKING 2) STOPPED INSPECTION, COMPLETE ALL AND RECALL |
|
07/08/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :*/ 1) NOT READY ALL TRADES NOT COMPLETE |