Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM01852
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/25/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :*/ 1) SEE ITEMS FROM LAST INSPECTION (BEAM HANGERS) NOT ON PLAN, MISSING NAILS 2) MISSING NAILING ON ROOF 3) NAIL HORIZONTAL JOINTS FRONT SHEAR 4) SCUPPER EAST SIDE, NOT CUT IN PROFFESIONAL MANNER 5) REAR PORCH ROOF NOT TIED TO SIDE WALL (SEE ?) | |
06/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) MISSING WIND BRACING WEST WALL 2) ROOF NAILING MISSING THRU OUT 3) CABIN TIE ALL CORNERS NNOT LAPPED 4) AT REAR PORCH BOTH SIDES NOT TIED TO WALL AT ROOF MISSING PLYWOOD AT ENDS 5) TIE BAY WINDOW WALLS TOGETHER 6) REAR PORCH BEAM NOT STRAPED 7) P.A. EAST WALL IS OUT OF POUR, NEED RETRO FIX 8) TWO NAILS IN EACH WIND BRACE END 9) ENTRY TO KITCHEN FROM HALL, BEAM HANGER MISSING NAILS 10) NEED TRUSS DRAWING 11) BEAM TO GIRDER TRUSSES INTERIOR NOT PLAN, SOME NAIL MISSING IN THEM 12) ADD STUDS UNDER TRIPLE GRIDER TRUSS 13) DOES ROOF GET TILE OR METAL 14) NEED TJI PORTION OF ROOF TO WALL AT LEDGER 15) HIP HANGERS MISSING NAILS |