Permit: T04CM01848

Parcel: 12709012C

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
06/22/2004 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*/ OK WALLS.
06/14/2004 ELECTRIC - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) PROTECT M/C CABLE AT SHALLOW STUDS. 2) FINISH SWITCHES. OK WALLS EXCEPT AS NOTED.
06/09/2004 ELECTRIC - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) PROTECT MC CABLE IN CHANNEL OF STUD 300-4. 2) MC TO BE SUPPORTED WITHIN 12" OF BOX AND AT 6' INTERVALS 330-10.