Permit: T04CM01829

Parcel: 13331162B

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
07/14/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*/ 1) ELECTRICAL FINAL APPROVED 2) POWER CLEARANCE, TEMP OR PERMANENT SUBJECT TO OTHER INSPECTION (NOT FINALED YET)
06/15/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
06/14/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/ 1) PLEASE PROVIDE GFCI PROTECTION FOR ALL THE KITCHEN COUNTER RECEPTACLES. NOTE: A CLEARANCE WILL NOT OCCUR UNTIL REPAIRS UNRELATED TO THIS PERMIT IS MADE OR FOLLOWS. THE GROUNDING ELECTRODE CONDUCTOR FOR THE SERVICE HAS BEEN CUT AND REMOVED. PLEASE HAVE A LICENSED ELECTRICAL CONTRACTOR OBTAIN A 1 HOUR GENERAL REPAIR PERMIT AND MAKE APPROPRIATE GROUNDING REPAIRS/ INSTALLATION - 4 SERVICE SECTION.