Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 07/01/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :*/ CORRECTIONS MADE OK. 2) OK TO COVER ALL AREAS. |
| 06/30/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 06/29/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ 1) NEED TO SEE WTR TEST ON ABS NEED TO SEE CLOSET FLANGES. 2) COPPER WTR PIPING OK. PRESSURE TEST OK. 3) A TRAP ARM MAY NOT CHANGE SIZE - GRADE IS TO BE 2% PERIOD. 4) HANGERS REQUIRED AT END OF BRANCHES, CHANGES OF DIRECTION AND CHANGES OF ELEVATION. 5) OK TO COVER SUBJECT TO WTR TEST. |