| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/ CORRECTIONS MADE OK. 2) OK TO COVER ALL AREAS. | |
| 06/30/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 06/29/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) NEED TO SEE WTR TEST ON ABS NEED TO SEE CLOSET FLANGES. 2) COPPER WTR PIPING OK. PRESSURE TEST OK. 3) A TRAP ARM MAY NOT CHANGE SIZE - GRADE IS TO BE 2% PERIOD. 4) HANGERS REQUIRED AT END OF BRANCHES, CHANGES OF DIRECTION AND CHANGES OF ELEVATION. 5) OK TO COVER SUBJECT TO WTR TEST. |