Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/18/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/1)SOIL WATER TEST IS OK 2)OVERHEAD WATER DISTRIBUTION IS OK 3)NOTE: SHALL USE A DIRECTIONAL FITTINGS FOR EXTENDING OF C.O. IN WEST UNIT @ LAVATORY
10/12/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/1)TRAP ARMS TO BE INSTALLED AT 1/4" PER FOOT 2)1 1/2" TRAP ARM MAY NOT EXCEED 3'6" DEVELOPED LENGTH 3)HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A SWEEP 4)ALL HORIZONTAL OVER HEAD PIPING TO BE SUPPORTED. 5)PLUMBERS TAPE NOT AN APPROVED STRAP
10/11/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :NO TEST ON ABS
PLUMBERS TAPE IS NOT APPROVED STRAP