Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM01785
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
07/06/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) NOTE 21 CALLS FOR INSULATION ON BOTH HOT AND COLD PIPING. CLOSET FLANGES OK WATER TEST WASTE AND VENT THRU ROOF OK 2) SECURE HOT PIPING OVERHEAD AND EXPANSION TANK FOR WATER HEATER. CAN VIEW THESE ITEMS AT LATER DATE | |
06/25/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) INSTALL PER YOUR PLAN - SEE NOTE #21. 2) SEE 94 UPC SECTION 511.0 FOR ACCESS AND WORKING SPACE FOR WTR HTRS AND PROVIDE WTR HTR PAN DRAIN PER PLAN. 3) PROVIDE HANGERS FOR ABS VENT PIPING. 4) SECURE OVERHEAD H20 PIPING PRPERLY. 5) INSTALL DUTCHMAN IN CLOSET FLANGE. - SEE NOTE 5 PREVIOUS INSP |