Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM01785
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/30/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
06/11/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ 1) WATER TEST UNDERGROUND ONLY 3" BLDG DRAIN CONNECTED TO EXISTING, EXISTS SOUTH 3 X 2 COMBO FOR LAUS, 3" SWEEP TO 3" FIG 5 FOR STOOLS OK 2) HAVE YOUR ARCHITECT PROVIDE WASTE, VENT AND WATER ISOMETRIC OF YOUR INSTALLATION CITY APPROVED 3) 3" FULL SIZE UPPER TERMINAL CLEANOUT SHALL BE REQUIRED 4) 2" CLEANOUT TEE SHALL BE REQUIRED AT LAVS 5) WATER TEST THRU ROOF INTERMEDIATE VENT PIPING 6) CLOSET FLANGE TO BE FLUSH WITH DRAINAGE PIPE AT STOOLS. PRIOR TO SETTING STOOLS 7) COVER AT OWN RISK |