Permit: T04CM01771

Parcel: 11623086A


Addresses:

730 S KROEGER LN

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
03/15/2005 ROOF NAILING Approved IVRS - Inspection :*
03/08/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PLAN CALLS FOR 7/8" ANCHOR (LEDGER BOLTS)
2) INSTALL ALL SLIDING DOORS
3) NOT INSTALLED OR APPROVED; GROUND RODS USED INSTEAD
4) NO TEST DWV OR POTABLE H20
5) INSTALL 12" X 12" ATTIC VENTS PER PLAN
6) NEED APPROVED TRUSS DRAWINGS
7) INSTALL SKYLIGHTS PER PLAN
8) TIGHTEN ALL NUTS ON BOLTS
9) NEED POSITIVE CONNECTION PORCH BEAM TO CORBELS AND POSTS
10) LEDGER BOLTS MISSING PARALLEL TRUSSES TO WALL
11) HAVE PA STRAP DELETIONS APPROVED
12) MUST COMPLETE ALL TRADES
13) THEN CALL FOR ALL INTERMEDIATE INSPECTIONS
14) STOPPED INSPECTION