Permit: T04CM01749

Parcel: 123122410


Addresses:

1405 E GRANT RD

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/04/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*
04/30/2004 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :$
04/28/2004 MECHANICAL - FINAL Partial Approval IVRS - Inspection :
See detailed listing on site.| 999*
04/26/2004 MECHANICAL - FINAL Partial Approval CORRECTIONS REQUIRED: 1) NEED ACCESS INSIDE OF HOUSE TO CHECK RETURN AIR DUCTING. 2) GAS LINE, PRESS TEST, 14 PSI, OK. ON ROOF AT UNIT, NEED LONGES NIPPLE AT UNIT. FLARE NUT ON FLEX GAS LINE IN GASKET ON UNIT CASING. 3) CONDENSATE PIPING, DRAIN LINE IS IN DOWNSPOUT - AT REAR OF HOUSE - DRAINING ONTO SIDEWALK. THIS IS A DANGEROUS HAZARD. RE-RUN TO ACCEPTABLE TERMINATION.