Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/23/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO ACCESS TO ATTIC 2) CONDENSATE MISSING 90 DEGREE ELBOW 3) PAPERWORK NOT COMPLETE 4) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT INTO JUNCTION BOX |
|
| 11/22/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SECONDARY CONDENSATE MISSING 90 DEGREE ELBOW 2) GFCI RIGHT SIDE OF SINK NOT ON GFCI CIRCUIT 3) CLEAN FAU SECONDARY FANS SPARK PLATES NOT INSTALLED PER MANUFACTURERS INSTALL INST. (FIG 17) 4) CAT WALK AT ATTIC ACCESS NOT COMPLETE 5) NOTE OF RECORD OUTLET UNDER BREAKFAST BAR JUNCTIONED OFF |