Permit: T04CM01699

Parcel: 140375050


Addresses:

6000 E TERCEL DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/29/2004 FRAMING Approved IVRS - Inspection :*
07/28/2004 FRAMING Denied IVRS - Inspection :SEAL LATH PENETATION UNDER KITCHEN WINDOW
FLEX DUCT INSIDE RADIUS OF ANY BEND SHOULD NOT BE LESS THAN 1/2 THE INSIDE DIAMETER OF THE DUCT
07/27/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) WILL APPROVE FRAMING WHEN ALL TRADES ARE COMPLETE 2) NAIL PROTECT WATER LINES AT MASTER BATH 3) NAIL PROTECT DWV AT MASTER BATH 4) GAS TEST AT 6 PSI, 10 PSI MINIMUM REQUIRED 5) CHECK FLEX DUCTS FOR TO MUCH COMPRESSION
07/23/2004 FRAMING Denied IVRS - Inspection :COMPLY WITH DETAIL GASD3 4SD4
PROVIDE 30" OF WORKSPACE IN FRONT OF FAN
CHECK FLEX DUCT FOR TOO MUCH COMPRESSION
LOOSE RED HEADS
REPLACE GREEN PLATE AT LAUNDRY ROOM