Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 08/03/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :*/ 1) ABS DWV THRU ROOF OK 2) PEX OK 3) TUBS OK 4) CLOSET FLANGES OK 5) OK TO COVER ALL AREAS |
| 08/02/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PLEASE HAVE PLUMBER ON SITE AT TIME OF NEXT INSPECTION |
| 07/30/2004 |
PLUMBING - INTERMEDIATE |
|
Denied |
1) SHALL PROVIDE A HANGER FOR ALL HORIZONTAL VENTS 2) HORIZONTAL VENTS SHALL BE LOCATED 6" ABOVE THE FLOOD RIM LEVEL 3) SPACE USE DRAINAGE/DIRECTIONAL FITTINGS FOR FLAT VENT FOR 2ND FLOOR TUB 4) SHALL PROVIDE SAFETY PLATES FOR WATER DISTRIBUTION CHECK ALL AREAS 5) SHALL USE L. SWEEP FOR VERTICAL TO HORIZONTAL DRAINAGE AT A. WASHER 6) UNIT #A IS OK WASTE, VENT AND WATER DISTRIBUTION |
| 07/29/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) NO TEST 2) PLEASE COMPLETE WORK BEFORE CALLING FOR INSPECTION |
| 07/16/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ 1) UNDERSLAB UNIT ONE OK TO COVER |