Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/18/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEE LAST INSPECTION 2) A MINIMUM OF 1/4" OF ROMEX SHEATHING MUST BE INSIDE FAN ASSEMBLY 3) LADDER BLOCKING BUSTED 4) OVER NOTCHED STUDS IN KITCHEN WALL 5) ELECTRICAL BOX LAYING ON FLOOR 6) MOVE ELECTRIC WIRES AWAY FROM GUSSET PLATE 7) NEXT FAILURE WILL BE REFEE |
|
| 06/16/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) STUDS AT KITCHEN WALL CUT 2) NO TEST ON DWV'S OR WATER LINES 3) PROVIDE FHA STRAPS AT DOUBLE TOP PLATE PER SEC. 602.6.1 2000 IRC 4) CLIP HEADERS, SHIM 3 POINT TRUSSES 5) STOPPED INSPECTION. HAVE TRADES WALK HOUSES |