Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2004 | ROOF NAILING | Approved | IVRS - Inspection :*/ 1) PLUMBING AND ELECTRIC OUT OF WALL AT LAUNDRY AND NOT PROTECTED 2) NO DWV WATER TEST 3) PHONE AND SECURITY WIRE BELOW CEILING W/BR 4) FIREBLOCK DROP CEILING 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF WALL SURFACE GARAGE, FP, ? MSTR BEDROOM ?? 6) DUCT RESTRICTED AT NOOK 7) M/BATH W/C VENT OUT OF WALL | |
| 07/12/2004 | ROOF NAILING | Partial Approval | IVRS - Inspection :* | |
| 07/08/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/01/2004 | ROOF NAILING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection. Truss rti not bearing roof Sheathing-provide city approved truss repair documents. Comply with all prior items. No plans or truss documents on site |
|
| 06/24/2004 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CORRECT ALL ITEMS AND RECALL |
|
| 06/15/2004 | ROOF NAILING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |
|
| 05/24/2004 | ROOF NAILING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* |