Permit: T04CM01665

Parcel: 138242250

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/30/2004 ROOF NAILING Approved IVRS - Inspection :*/ 1) PLUMBING AND ELECTRIC OUT OF WALL AT LAUNDRY AND NOT PROTECTED 2) NO DWV WATER TEST 3) PHONE AND SECURITY WIRE BELOW CEILING W/BR 4) FIREBLOCK DROP CEILING 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF WALL SURFACE GARAGE, FP, ? MSTR BEDROOM ?? 6) DUCT RESTRICTED AT NOOK 7) M/BATH W/C VENT OUT OF WALL
07/12/2004 ROOF NAILING Partial Approval IVRS - Inspection :*
07/08/2004 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
07/01/2004 ROOF NAILING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection. Truss rti not bearing roof Sheathing-provide city approved truss repair documents. Comply with all prior items. No plans or truss documents on site
06/24/2004 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) CORRECT ALL ITEMS AND RECALL
06/15/2004 ROOF NAILING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
05/24/2004 ROOF NAILING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*