Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 07/12/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) REPAIRS MADE PER REPAIR DOCUMENTS. PENDING CITY OF TUCSON DOCUMENT APPROVALS | |
| 07/08/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) TRUSS RT1 REPAIR DOCUMENT MUST BE APPROVED BY CITY OF TUCSON 2) TWO FEET OF ROOF SHEATHING NOT SUPPORTED BY ROOF TRUSS RT-1 MAXIMUM ALLOWED OSB SPAN 24" PRESENTLY NON SUPPORTED FOR 48"-PROVIDE REPAIR 3) ITEMS 5 OF 6/15/04 NOT COMPLIED WITH, ALSO ITEM NUMBER 9 4) ENTRY OVERFRAME MISSING BLOCKING AT 24" ON CENTER SEE S5 5) ROOF SHEATHING NOT NAILED TO TRUSS RT-1 STAPLES TOO SHORT. RENAIL TO REPAIR 6) ROOF SHEATHING NOT NAILED AT 15/A8 |
|
| 06/15/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) TRUSSES COVERED WITH VAPOR BARIIER-UNABLE TO TELL IF TRUSSES DAMAGED. EXPOSE 2) TRUSS RT1 NOT BEARING ROOF SHEATHING-SCABBEDE PROVIDE APPROVED TRUSS REPAIR DOCUMENTS 3) PROVIDE INFO ON CONSTRUCTION OF SHEAR PANEL ON 15/18 WHAT OSB THICKNESS ? WHAT NAIL AND SPACING ON NAILS FOR OSB TO 2 X FRAME 4) A 35 CLIPS MISSING AT TRUSSES 15/A8 5) PAGE A-5 SPECIFIES GARAGE SHEAR WALL #3 A5.1 CALLS IT SHEAR WALL #1 HAVE PLAN REVISED TO CORRECT SHEAR WALL OR BLDG TO SW3 6) PROVIDE FOR SHEAR TRANSFER IN MASTER BEDROOM CLOSET 7) NAIL SHEAR STUDS WITH HOLDOWNS 8) NAIL #4 SHEAR AT 8 FT SEAM 4" ON CENTER 9) UNABLE TO INSPECT TRUSSES AT T1-11 REMOVE 10) NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE |
|
| 05/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950*/ 1) NO CITY OF TUCSON APPROVED TRUSS DRAWINGS ON SITE 2) TRUSSES COVERED WITH VAPOR BARRIER WITHOUT INSPECTION-UNABLE TO TELL IF TRUSSES DAMAGED UNCOVER 3) YOU MUST PROVIDE OSHA APPROVED LADDER ACCESS TO ROOF 4) 14/A8 NOT COMPLED WITH AT 4' ON CENTER 5) GARAGE REQUIRES TRIPPLE KING STUDS 6) 15/A8 NOT COMPLIED WITH 7) STOPPED INSPECTION, TOO MANY ITEMS |