Permit: T04CM01649

Parcel: 120082630


Addresses:

4757 S 7TH AV #01

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/08/2004 PLUMBING - FINAL Approved IVRS - Inspection :*/1)GAS PRESSURE TEST IS OK
2)GAS SHUT OFF VALVES OK
3)WATER HTR FLU VENT, T&P VALVE & DRAIN OK
4)WALL FURANCE OK
08/11/2004 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SHALL PROVIDE A VARIENCE FORM FROM OUR OFFICE FOR ALTERNATE METHOD OF INSTALLATION OF T&P DRAIN. 2) SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT FOR WTR HTR FLU VENT AND AT APPLIANCE COLLAR. 3) SHALL PROVIDE HARD PIPE INTO WALL FURNACE THEN CONNECT FLEX CONNECTOR. 4) RE TEST SYSTEM 10 LBS