Permit: T04CM01649

Parcel: 120082630


Addresses:

4757 S 7TH AV #01

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
10/21/2004 ELECTRIC - FINAL Approved IVRS - Inspection :* OK TO CLEAR METER 1
10/19/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
10/15/2004 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*/NOTE: 1)SCREW MISSING ON OUTSIDE PANEL DEADFRONT 2)COPYS OF INSPECTIONS MUST BE LEFT ON SITE WITH PERMIT CARD
10/14/2004 ELECTRIC - FINAL Denied IVRS - Inspection :HOLD OVER FOR FRIDAY FOR DAN SANTA CRUZ
10/06/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
NOTES: A RE INSPECTION FEE WILL BE ASSESED 1) I.D NEUTRAL CONDUCTOR WHITE FOR FEEDERS IN PANEL OUTSIDE. 2) USE PROPER METAL COVER PLATES FOR J-BOXES IN ATTIC, PLASTIC TRIM TYPE PLATES NOT APPROVED FOR METAL J-BOXES ON BOTTOM OF TRUSSES. 3) USE PROPER COVER PLATES FOR RECEPTS IN HANDY BOXES. PLASTIC PLATES ARE LISTED FOR FLUSH INSTALLATIONS.