Permit: T04CM01622

Parcel: 141015580

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM01622

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/06/2004 FRAMING Approved IVRS - Inspection :*
08/02/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) FROM LAST INSPECTION: TUB SHOE LEAKING NORTH TUB 2) INSTALL BACKING AT TUB SIDES, BOTH TUBS MARKED ON FLOOR
07/21/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) INSTALL BLADDER AT MAIN CLEANOUT H2O TEST ENTIRE SYSTEM 2) RAISE CHICAGO LOOP AS HIGH AS POSSIBLE 3) REMOVE H2O FROM FLOOR OUTLET 4) BLOCK ALL MECH DUCTS 5) BANG PLATE AT LAUNDRY, ALL PIPES AND WIRES 6) PLUG SEWER VENT 7) NEED T/P VALVE 8) FOOT VENT FOR CHICAGO LOOP GETS A CLEANOUT 9) INSTALL BACKING FOR TUB/SHOWER ALL AROUND 10) BANG PLATE DRYER DUCT 11) 3" VENT/DRAIN LEAKING 12) SMOKE DETECTOR CAN LITE NOT SECURED 13) BACKING IN CORNER HALL BATH NORTH 14) FILL TUBS WITH H2O 15) DIVERTORS TO BE ANTI-SCALD 16) CLOSET LITES 12" FROM SHELF