Permit: T04CM01619

Parcel: 123172660


Addresses:

1434 E ELM ST #02


Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T04CM01619

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
06/06/2006 ROOF NAILING Approved IVRS - Inspection :*
06/02/2006 ROOF NAILING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER PAPERWORK TURNED IN BY INSPECTOR R. CAMACHO
05/30/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MANY LOOSE SHEETS THROUGHOUT
2) SHEETS NOT SPANNING 2 BAYS MUST BE BLOCKED AND NAILED OR REPLACED
3) STOPPED INSPECTION
03/16/2006 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PER TRUSS CALC'S THIA26 HANGERS REQUIRED DBL GIRDER JACK TRUSS CONNECTION A06 TO X6
2) NAIL EVERY HOLE H.25
3) ALL 2 POINT BEARING TRUSSES REQUIRE 1/2" CLEARANCE FOR DEFLECTION INTERIOR WALLS
4) MANY LOOSE SHEETS
5) NAIL ALL EDGES AND FIELD PROPERLY-ROOF PANELS MUST SPAN 3 TRUSSES OR 2 BAYS
-------------------------------------------------------------------------------------------------
1) MISSING EXTERIOR GFI
2) EXTERIOR LIGHT FIXTURE MISSING ENTRY DOOR
3) PIG TAIL GROUND SWITCHES BEDROOM 3
4) PIG TAIL ALL GROUNDS IN SWITCH BOXES THROUGHOUT
5) PROVIDE COPPER BOND
6) BLOCK REGISTER BOOTS 3 SIDES
7) STOPPED INSPECTION
12/12/2005 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE SAFE ACCESS TO ROOF
2) FRAMING TO BE INSPECTED AT INTERMEDIATES