Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/13/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :*/ 1) INSTALL POSITIVE CONNECTION LOWER PORCH ROOF TO BEARING AT HOUSE CONNECTION | |
| 08/25/2004 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* | |
| 08/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INSTALL POSITIVE CONNECTION PORCH LEDGER TO BEARING BEHIND 2) INSTALL FHA STRAPS EXTERIOR PLATES AT PLUMBING CUTS 3) H2.5'S MISSING SEE DETAIL 5 PAGE S-2 4) NAIL OFF SHEATHING 5) NEED LADDER TO INSPECT ROOF 6) STOPPED INSPECTION |
|
| 08/17/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SHEARWALLS NOT NAILED 2) INSTALL STRAPS TO 1ST TO 2ND FLOOR EXTERIOR 3) INSTALL STRAPS BEAMS TO POSTS TO PLATES 4) STRAP ALL BEAMS TO BEARING 5) CARRY 2ND FLOOR BEARING CONTINOUS TO FIRST FLOOR 6) INSTALL FHA STRAP EXTERIOR WALLS AT PLUMBING CUTS 7) NEED LADDER TO INSPECT ROOF 8) STOPPED INSPECTION |