Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T04CM01613
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/09/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
06/04/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ WTR TEST ON DRAINAGE FOR FOOT SPAS FROM FLOOR SINK TO FLOOR SINK THRU ROOF PER PLAN. H20 PIPING PARTIAL APPROVEL. 1) NEED INSTALLATION OF BACKFLOW DEVICES FOR FUTURE FOOT SPA CHAIRS AND NEED TO SEE PIPING WRAPPED AT UNDERGROUND PENETRATION THRU CONCRETE BEFORE POUR. PARTIAL APPROVAL PER STEVE LONG THIS INSP. | |
05/21/2004 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :*/ 1) WASTE AND VENT FOR FLOOR SINK AND HAND SINK. WATER TEST OK ONLY. THRU ROOF 2) WATER PIPING INSTALLED PER PLAN WATEE TEST OK. SEE NOTE #3 ABOVE CORRECT DRAINAGE FOR FOOT SPA'S AND CALL FOR INTERMEDIATE 2) WRAP PIPING IN AREA OF CONCRETE POUR BACK AND CALL IN FOR INSPECTION PRIOR TOP POUR BACK | |
05/19/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) WTR TEST ALL WASTE AND VENT PIPING - SANATACS TEES ARE VERTICAL DRAINAGE ONLY. 2) H2O PIPING TO BE INSTALLED PER PLAN. 3) PLEASE SEE CHAPTER 8 SPECIAL AND INDIRECT WASTE FOR FOOT SPAS DRAINAGE. THIS PLAN MAY BE APPROVED IN ERROR. |