Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01609

Parcel: 133104070

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM01609

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/02/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/28/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection
07/27/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) H3 CLIPS MISSING FROM LEDGERS 9/D2 2) TJI HANGER TABS NOT BENT AND NAILED THROUGHOUT 3) 2/A3 NOT COMPLIED WITH AT SHEARWALL. WALL MUST EXTEND TO ROOF SHEATHING 4) H2.5 CLIPS AND BLOCKING MISSING PER 6/D2 5) BEAM NOT CLIPPED TO POST REAR PORCH POST BASE NOT CLIPPED 6) MANY TRUSSES NOT CLIPPED 7) TRUSSES NOT BLOCKED PER 9/D2 8) NO LADDER ACCESS TO ROOF 9) STOPPED INSPECTION, TOO MANY ITEMS