Permit: T04CM01608

Parcel: 140107120

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/03/2004 FRAMING Approved IVRS - Inspection :*
06/02/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) CRIPPLES UNDER WINDOWS NOT BEARING 2) PROVIDE 1" CLEARANCE FROM COMBUSTIBLES AT B-VENTS 3) FIRE BLOCK WATER HEATER PLATFORM 4) ATTIC ACCESS BLOCK FLEX DUCT 5) NAIL PROTECT PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD AND ELECTRICAL WITHIN 1 1/4. STOPPED INSPECTION
06/01/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BLOCK MECHANICAL BOOT 3 SIDES WASH ROOM 2) 1" CLEARANCE REQUIRED TO COMBUSTIBLES AT W/H "B" VENT 3) TRUSS BRACE MISSING INT ABOVE DEN 4) RED HEAD ANCHOR BOLTS LOOSE THROUGHOUT
05/28/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BLOCK AIR GRILL AND WASHROOM 3 SIDES MASTER BEDROOM 2) FIRE BLOCK MASTER BEDROOM TOILET VENT 3) 1" CLEARANCE REQUIRED AT 'B' VENT 4) NEED ENGINEERED TRUSS REPAIR 5) STOPPED INSPECTION 6) REFEE DUE PRIOR TO INSPECTION
05/27/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) NEED INTERMEDIATES COMPLETE 2) BLOCK IN KITCHEN WALL 3) REPAIRS TO RUSS D/10E REPAIRED AS REQUIRED BY TRUSS COMPANY 4) SUPPLY OK 5) NO DWV WATER TEST