Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01604
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/02/2005 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/14/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) FAMILY ROOM ADDITION-GARAGE NOT READY 2) BASE BOARD ELECTRIC HEATERS MUST BE HARD WIRED AND ON A DEDICATED CIRCUIT 3) MAKE UP (CONNECT) ALL GROUND WIRES IN ELECTRIC BOXES AND SECURE WITH MECHANICAL FASTENER. PROVIDE A SEPERATE GROUND PIG TAIL FOR EACH SWITCH AND OUTLET 4) GROUND ALL METAL ELECTRIC BOXES 5) ALL JUNCTION BOXES MUST BE ACCESSIBLE AFTER DRYWALL IS INSTALLED 6) DRYWALL SCREWS NOT ALLOWED TO SECURE FAN BOX. USE #10 WOOD OR METAL SCREWS |