Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T04CM01579
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/10/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/26/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/1)INSTALL RETURNS 1/3 POINTE? BOTTOM CHORD GARAGE TRESSED? HEADER SIZES NOT PER PLAN 2)ADDITIONAL WALL ADDED GARAGE WITH MECHANICAL ROOM NOT ON PLANS 3)STAIR RISE MAX 7 3/4" & NOT A STAIR RUN MIN 10" TO EXCEED 1/4" MAX. FROM EACH ONE 4)APPEARES MASONRY OR WOOD POST OMITTED REAR PORCH AT BEAM BEARING 5)NEED TO EXPOSE BOTTOM OF PORCH POST TO VERIFY POSITIVE CONNECTION 6)PLAN CALLS FOR 5/8" DIAMETER LEDGER BOLTS @ 16" CENTER SPACING 7)NEED VERIFICATION LEDGER TO STUDS POSITIVE CONNECTION 8)IN POSITIVE CONNECTION UPPER WALK DECK PONY WALL TO BEAMS BELOW 9)STOPPED INSPECTION |
|
| 11/23/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED LADDER TO INSPECT ROOF 2) NEED APPROVED TJI DRAWINGS |