Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01579

Parcel: 10319002K

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T04CM01579

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/10/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/26/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/1)INSTALL RETURNS 1/3 POINTE? BOTTOM CHORD GARAGE TRESSED? HEADER SIZES NOT PER PLAN 2)ADDITIONAL WALL ADDED GARAGE WITH MECHANICAL ROOM NOT ON PLANS 3)STAIR RISE MAX 7 3/4" & NOT A STAIR RUN MIN 10" TO EXCEED 1/4" MAX. FROM EACH ONE 4)APPEARES MASONRY OR WOOD POST OMITTED REAR PORCH AT BEAM BEARING 5)NEED TO EXPOSE BOTTOM OF PORCH POST TO VERIFY POSITIVE CONNECTION 6)PLAN CALLS FOR 5/8" DIAMETER LEDGER BOLTS @ 16" CENTER SPACING 7)NEED VERIFICATION LEDGER TO STUDS POSITIVE CONNECTION 8)IN POSITIVE CONNECTION UPPER WALK DECK PONY WALL TO BEAMS BELOW 9)STOPPED INSPECTION
11/23/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NEED LADDER TO INSPECT ROOF
2) NEED APPROVED TJI DRAWINGS