Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/02/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL PENETRATIONS FRONT ENTRY 2) FRONT WINDOW NOT SEALED 3) DISSIMILAR METALS NOT ALLOWED TO TOUCH 4) SEAL GAPS 5) REAR DORMER NOT LATHED 6) NAIL PROTECT ELECTRIC WITHIN 1 1/4 FROM EDGE OF STUD 7) SEAL ALL LATH PENETRATIONS FROM INSIDE 8) PANCAKE BOX IN BEDROOM NOT GROUNDED 9) SHIM HEADERS 10) CRIPPLES UNDER WINDOWS NOT BEARING 11) STOPPED INSPECTION |
|
| 06/01/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO GAS BOND 2) BEARING STUDS NOTCHED GREATER THAN 25 PERCENT BY WATER HEATER 3) RED HEAD ANCHOR BOLTS LOOSE 4) CAULK STUCCO LATH MISSING |
|
| 05/28/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) COMPLETE STUCCO MESH PRIOR TO INTERMEDIATES |