| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 05/21/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CLIPS NOT NAILED PER MANUFACTURERS INSTALL INSTRUCTION 2) CHECK OVERSPANS CRIPPLES 3) STRAP CORNER NOT CABIN TIED |
|
| 05/20/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) REPLACE BROKEN STUD AT GARAGE WALL 2) CHECK FOR OVERSPANS 3) CLIPS NOT NAILED PER MANUFACTURER INSTALL INSTRUCTIONS 4) GABLE TRUSS NOT BEARING ON DOUBLE TOP PLATE 5) SHEAR TRANSFERS NOT NAILED PER PLAN 6) PC OF OSB INSTALLED UPSIDE DOWN |