Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T04CM01539
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2004 | FRAMING | Approved | IVRS - Inspection :* | |
06/18/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) 16 LF OF HORIZONTAL DRAIN REQUIRES 4" OF PITCH 94 UPC 708.0 2) NEXT FAILURE WILL BE CHANGED A REINSPECTION FEE 3) BUILD TO PLAN OR REVISE PLAN TO AS BUILT | |
06/17/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) ELECTRIC BOX HANGING IN GARAGE 2) 3D6 NOT COMPLIED WITH |
|
06/16/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SECOND FLOOR SEWER DRAINS REQUIRE 1/4"/FT PITCH 2) GARAGE TRUSS BLOCKS REQUIRE 8-16D NAILS EACH BLOCK 3/D6 3) ANCHOR BOLTS LOOSE 4) HORIZONTAL VENT BELOW 42" NOT ALLOWED |