Permit: T04CM01528

Parcel: 140374980


Addresses:

6066 E GULL CT

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
09/29/2004 BUILDING - FINAL Approved IVRS - Inspection :*/ 1) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT. DO NOT ADD AN OUTLET
09/28/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) CIRCUIT #20 NOT IDENTIFIED AND USING #12 WIRE ON 15 AMP BREAKER 2) SCREEN MISSING AT WAHSER PAN DRAIN 3) BACK PATIO LID NOT SEALED AT EDGES 4) SEAL HOLE AT GARAGE OPENER STUB OUT 5) REST OF HOUSE OK 6) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT
09/24/2004 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BACKWATER VALVE NOT ACCESSIBLE 2) FINAL GRADE NOT COMPLETE 3) UFER CLAMP MISSING OR BURRIED IN STUCCO 4) EXHAUST FAN MISSING FLAPPER 5) SCREEN MISSING FOR WASHER PAN DRAIN 6) STOPPED INSPECTION