Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :*/ 1) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT. DO NOT ADD AN OUTLET | |
| 09/28/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) CIRCUIT #20 NOT IDENTIFIED AND USING #12 WIRE ON 15 AMP BREAKER 2) SCREEN MISSING AT WAHSER PAN DRAIN 3) BACK PATIO LID NOT SEALED AT EDGES 4) SEAL HOLE AT GARAGE OPENER STUB OUT 5) REST OF HOUSE OK 6) NOTE OF RECORD: OUTLET UNDER BREAKFAST BAR BLANKED OUT |
|
| 09/24/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BACKWATER VALVE NOT ACCESSIBLE 2) FINAL GRADE NOT COMPLETE 3) UFER CLAMP MISSING OR BURRIED IN STUCCO 4) EXHAUST FAN MISSING FLAPPER 5) SCREEN MISSING FOR WASHER PAN DRAIN 6) STOPPED INSPECTION |