Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/02/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) H2.5 HIP TRUSSES AT TOP PLATES 2) BLOCK TRUSSES PER PLAN 3) NEED HIP TRUSS CONNECTION TO GIRDER TRUSS DETAIL WITH CONNECTION HARDWARE DESCRIBED 4) SHIM HEADERS WHERE NEEDED 5) FINISH MESH ATTACHMENT |
|
| 07/01/2004 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |