Permit: T04CM01462

Parcel: 12507172A


Addresses:

2525 E 6TH ST


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T04CM01462

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
06/07/2004 MECHANICAL - FINAL Approved IVRS - Inspection :*
05/25/2004 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) PROVIDE MIN. 1" CLEARANCE FROM COMBUSTABLES WHERE WATER HTR VENT PENETRATES THE CEILING AND ROOF. 2) REMOVE SCREW FROM DRYER VENT ON ROOF. SECURE VENT CAP. YOU CAN USE POP RIVETS. SEAL AROUND TERMINATION. 3) EXTEND WTR HTR VENT 2' ABOVE WALL ON ROOF. 4) TERMINATE CONDENSATE INTO AN APPROVED LOCATION. 5) PROVIDE AN OUTSIDE AIR INTAKE ON A/C UNIT AS PER PLAN.