Inspection History: MECHANICAL - HOODS

Date Description Inspector Results Comments
09/15/2004 MECHANICAL - HOODS Approved IVRS - Inspection :*
09/14/2004 MECHANICAL - HOODS Cancelled PER CONTRACTOR
09/10/2004 MECHANICAL - HOODS Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) TIGHTEN BANDS ON FIRE WRAP. BE SURE OVERLAPS ARE MINIMUM 3". DO NOT USE SCREWS ON ACCESS DOORS ON GREASE DUCTS. FINISH WORK ON ROOF
08/16/2004 MECHANICAL - HOODS Partial Approval IVRS - Inspection :*/INSPECTED GREASE DUCTS. PROVIDE A CLEANOUT AT CHANGE OF DIRECTION
OK TO BUILD CHASE. BE SURE TO MAINTAIN MIN. 6" CLEARANCE INSIDE SHAFTS.