Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/02/2004 |
PLUMBING - ROUGH, SOIL |
|
Approved |
|
| 07/20/2004 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :*OK TO COVER |
| 05/24/2004 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection :*/ GREASE WASTE OK OK TO COVER. NEED TO SEE INTERCEPTOR. |
| 05/21/2004 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
1) SANITARY WASTE FROM GREASE INTERCEPTOR TO TIE-IN AT EXISTING OK 2) SANITARY WASTE CONNECTIONS IN KITCHEN OK TO COVER 3) REVISED GAS INSTALLATION WITH THOMAS THE DESIGN ENGINEER AND GAS IS MORE THAN ADEQUATELY SIZED NO ISO, NECESSARY |
| 05/20/2004 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PLAN APPROVED IN ERROR - NO ISOMETRIC FOR DWV, WATER OR GAS - 791-5550 EXT. 1147 - STEVE LONG. 2) ABS ROUGH IS IN TWO LEVELS - HAVE LOWER LEVEL INSPECTED THEN YOU CAN SHADE THE PIPE IN ORDER TO LAY THE GREASE WASTE OVER IT. 3) BACK PITCHED SECTIONS NOT APPROVED. SECTIONS WITH LESS THAN 1% TO BE CORRECTED. 4) DRAINS WITH PARTITIONS WITHIN THE TRAP ARM DISTANCE TO BE PIPED CONVENTIONALLY. 5) WHY IS FLOOR DRAIN PIPED TO GREASE WASTE? ONLY GREASE PRODUCING FIXTURES TO BE WASTED THRU INTERCEPTOR. 6) REDLINE CHANGE AT HAND SINK. |
| 05/19/2004 |
PLUMBING - ROUGH, SOIL |
|
Not ready for Inspection |
IVRS - Inspection :*/ TEST DOWN ON UNDERGROUND SOIL. |