Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2004 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/12/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SAME AS LAST INSPECTION |
|
| 07/09/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO DWV WATER TEST 2) PLUMB OUTSIDE OF WALL CAVITY 3) NON BEARING STUD BY WATER HEATER NOTCHED MORE THAN 40 PERCENT 4) PED CANNOT BE WITHIN 6' OF WATER HEATER "B" VENT 5) NAIL PROTECT A/C COPPER 6) NAIL PROTECT ALL PLUMBING AND ELECTRIC WITHIN 1 1/4" OF WALL SURFACE 7) SEAL ALL 2ND FLOOR PENETRATIONS 8) SUPPORT DWV HORIZONTAL AT 4' ON CENTER 9) CHASE FIRE STOP REQUIRES 2 LAYERS OF 1/2" OSB 10) GAS BOND NOT THRU WALL |