Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/23/2004 | BUILDING - FINAL | Denied | IVRS - Inspection :ELECTRIC PANEL APPROVED NO ACCESS TO HOUSE CALL FOR FINALS AFTER WINDOWS REPLACED WITH TEMPERED | |
| 07/21/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) RE-LABEL PANEL TO REFLECT ACTUAL DBL LUGGED BREAKERS MUST BE CORRECTED-ADD BREAKERS 2) WINDOWS MUST BE TEMPERED 3) RECEPTACLES WITHIN 5' OF TUB MUST BE GFI 4) UNDERGROUND ELECTRIC APPROVED PRIOR |
|
| 07/12/2004 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :*/ 1) HOLE IN BOTTOM FO SERVICE PANEL NEEDS TO BE PLUGGED 2) LABEL ALL CIRCUITS TO ROOM, 2 POLE BREAKER 60/60 LABELED GARAGE FAMILY ROOM WAS SWITCHED ON, NO WIRE NUTS ON OTHER END OF CIRCUIT 3) CHECK ALL BREAKERS FOR WIRE SIZE EXISTING BREAKERS 20/14 GAUGE WIRE 4) WAS UNDERGROUND ELECTRIC INSPECTED 5) SAFETY GLASS ISSUE, ALSO SAFETY GLASS REQUIRED AT SLIDING DOOR 6) EXISTING WINDOW CLOSER THAN 24" 6) 60 AMP CIRCUIT NEEDS TO TERMINATE IN A BOX 7) ALL OUTLETS TO BE GFCI PROTECTED 8) 2 CIRCUITS ON ONE BREAKER, ADD ANOTHER BREAKER |