Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2004 | FRAMING | Approved | NOTE: SAFETY GLASS IS NORMALLY ETCHED TO THAT EFFECT. NOTE: WINDOWS ON WEST WALL | |
| 06/08/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NEED RED HEAD ON WEST WALL BOTTOM PLATE, WITHIN 12" OF THE END 2) PROTECT WIRES WHERE THEY PROTRUDE THROUGH A STUD WITHIN 1 1/4" OF THE FACE 3) NO OUTLET UNDER EXISTING WINDOW-PER PLAN 4) WINDOWS DO NOT APPEAR TO BE SAFETY GLASS PER PLAN |
|
| 05/17/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SUBMIT AS BUILT FOR APPROVAL 2) ELECTRIC, BLDG AND MECH NOT PER PLAN 3) SLAB POURED WITHOUT INSPECTION 4) UNDER SLAB ELECTRIC COVERED WITHOUT INSPECTION 5) NO PA'S INSTALLED; ELECTRIC, FRAMING AND MECH INCOMPLETE |