Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM01430
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2004 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
10/11/2004 | BUILDING - FINAL | Cancelled | CANCELLED PER SUPER | |
10/07/2004 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) EXTEND CLEANOUTS TO GRADE AND PROVIDE THREADED CAB PRESENTLY UNDER 2) POST TENSION MUST BE PERMANENTLY STAMPED INTO CONCRETE WITH POST TENSION TAG ON WATER SERVICE 3) ELECTRIC GFCI OUTLET REQUIRED WITHIN 24" OF KITCHEN SINK 4) PROVIDE LADDER ACCESS TO ATTIC FURNACE |