Permit: T04CM01419

Parcel: 140374190


Addresses:

7051 S GULL LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/06/2004 FRAMING Approved IVRS - Inspection :*/ 1) RE-INSPECT
08/05/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) OK TO INSULATE 2) PLATFORM UNDER STAIRS NOT TREATED LUMBER 2) HD LEFT SIDE OF S.G.D. MISSING NAILS
08/03/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FRONT COLUMN NOT COMPLETE 2) NO TEST ON DWV'S UPSTAIRS 3) WATER LINES OK 4) NAIL PROTECT PLUMBING IN BATH UPSTAIRS 5) REPLACE OVER NOTCHED BEARING STUD AT NORTH EAST CORNER OF WATER HEATER STAND AND STRAP BEAM 6) SEAL PENETRATIONS AT PANTRY 7) LANDING UNDER STAIRS TOUCHING CONCRETE NOT TREATED LUMBER 8) FIRE BLOCK MISSING AT STAIR CLOSET 9) HOLDOWN MISSING LEFT SIDE OF S.G.D.
07/29/2004 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspection. Nail protect t & p line at garage. Provide approved detail for shimming gas at garage south wall. Stud missing under lsl at water heater bearing point. Scews penetrated romex left side of sgd. Stopped inspection
07/28/2004 FRAMING Denied IVRS - Inspection :
1 NAIL PROTECT T&P LINE AT GARAGE
2 DRYER VENT NOT INSTALLED
3 HORIZONTAL ROMEX RUNS REQ 1 1/4 CLEARANCE FROM EDGE OF BOTTOM CORD OF FLOOR TRUSS
4. LOOSD ANCHOR BOLT AT 2X6 PLATE KITCHEN
STOPPED INSP AT KITCHEN.
07/26/2004 FRAMING Not ready for Inspection IVRS - Inspection :*
05/12/2004 FRAMING Cancelled IVRS - Ri canceled