Permit: T04CM01418

Parcel: 140375080


Addresses:

5976 E TERCEL DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/16/2004 FRAMING Approved IVRS - Inspection :*
07/13/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) OK TO INSULATE 2) RE-FILL DWV'S TO CHECK NEW FITTING AT HALL BATH DIRTY ARM 3) WATER LINES OK
07/12/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) 1 1/2: TRAP ARM MORE THAN 42", RETEST DWV'S 2) COMPLY WITH SECTION 602.6.1 2000 IRC DRILLING AND NOTCHING
07/08/2004 FRAMING Not ready for Inspection IVRS - Inspection :*/ 1) CANCELLED ON SITE BY BOYD
07/07/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO TEST ON DWV'S 2) 2" TRAP ARM NOT ALLOWED AT LAV 3) NAIL PROTECT DRYER VENT 4) COMPLY WITH SEC R602.6.1 2000 IRC DRILLING AND NOTCHING TOP PLATE