Permit: T04CM01417

Parcel: 140374650


Addresses:

6228 E BRAMBLE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/13/2004 FRAMING Approved IVRS - Inspection :*/ 1) SEE LAST INSPECTION DATED 7/8/04 2) DO NOT INSULATE
07/12/2004 FRAMING Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
07/08/2004 FRAMING Partial Approval IVRS - Inspection :*/ 1) INTERIOR HOLDOWN MISSING NAILS 2) SEAL OPENING AT WASHER DRAIN PIPE 3) OK TO INSULATE
07/07/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) SEAL OPENING AT WAHSER PAN DRAIN 2) FLEX DUCT IN POWDER ROOM NOT INSTALLED PER MANUFACTURER INSTALL INSTRUCTIONS 3) WATER HEATER VENT PITCH NOT PER CODE 4) INTERIOR HOLDOWN MISSING NAILS
07/01/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) INTERIOR HOLDOWN MISSING 2) CHECK PITCH ON DRAINS 3) WATER HEATER VENT REQUIRES 60 DEGREE DROP 4) NO WATER IN KITCHEN AND POWDER ROOM VENTS
06/29/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) INTERIOR HOLDOWN MISSING 2) NO TEST ON DWV'S 3) RIM BOARD IN GARAGE NOT NAILED PER PLAN 4) GAS PRESSURE TEST AT 7 MORE OR LESS PSI, 10 PSI MINIMUM REQUIRED 5) STOPPED INSPECTION