Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2004 | FRAMING | Approved | IVRS - Inspection :*/ 1) SEE LAST INSPECTION DATED 7/8/04 2) DO NOT INSULATE | |
| 07/12/2004 | FRAMING | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspectio |
|
| 07/08/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) INTERIOR HOLDOWN MISSING NAILS 2) SEAL OPENING AT WASHER DRAIN PIPE 3) OK TO INSULATE | |
| 07/07/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) SEAL OPENING AT WAHSER PAN DRAIN 2) FLEX DUCT IN POWDER ROOM NOT INSTALLED PER MANUFACTURER INSTALL INSTRUCTIONS 3) WATER HEATER VENT PITCH NOT PER CODE 4) INTERIOR HOLDOWN MISSING NAILS |
|
| 07/01/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INTERIOR HOLDOWN MISSING 2) CHECK PITCH ON DRAINS 3) WATER HEATER VENT REQUIRES 60 DEGREE DROP 4) NO WATER IN KITCHEN AND POWDER ROOM VENTS |
|
| 06/29/2004 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) INTERIOR HOLDOWN MISSING 2) NO TEST ON DWV'S 3) RIM BOARD IN GARAGE NOT NAILED PER PLAN 4) GAS PRESSURE TEST AT 7 MORE OR LESS PSI, 10 PSI MINIMUM REQUIRED 5) STOPPED INSPECTION |