Permit: T04CM01389

Parcel: 136337550


Addresses:

9075 E 42ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - UNDERGROUND

Date Description Inspector Results Comments
08/16/2006 ELECTRIC - UNDERGROUND Approved
07/12/2006 ELECTRIC - UNDERGROUND Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INDENTIFY BREAKERS
2) FILL HOLE SIDE OF PANEL
3) SECURE A/C FLEX TO WALL WITHIN 12" OF DISCONNECT
4) GARAGE, KITCHEN AND OUTSIDE RECEPTACLES MUST BE GFI
5) INSTALL VACUUM BREAKERS ON HOSE BIBS
6) INSTALL 90 ON T/P LINE
7) CONNECT WATER HEATER B-VENT
8) BOND GAS PIPE
9) ALL BATH RECEPTACLES MUST BE GFI
10) OPEN GROUND MASGTER BATH RECEPTACLES
110 4 DINING RECEPTACLES INOPERABLE