Permit: T04CM01381

Parcel: 12414115A

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
07/16/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*/ 1) SOIL WATER TEST IS OK 2) NOTE: BLDG DRAIN IS STUBBED OUT OF BLDG AT TWO WAY CLEANOUT ONLY 3) 1 1/2" COPPER LOOP FOR BLDG WATEE SUPPLY IS OK 4) OK TO BACKFILL TRENCH
07/14/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MUST SLEEVE 4" BLDG DRAIN EXTENDING THRU FOOTER. CAN NOT EMBED ABS WASTE IN CONCRETE. 2) ROUGH PLBG NOT INSTALLED AS PER PLAN. 3) RETEST SYSTEM. 4) REMOVE ANY STONES THAT ARE AROUND SOFT COPPER LOOP.
07/13/2004 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*