Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T04CM01344
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/25/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
08/24/2006 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) PENDING CERTS |
|
07/24/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CONDENSOR DISCONNECT NEEDS 36" CLEARANCE FROM UNIT 2) EXPOSED WIRING MECH ROOM 3) INSTALL DRIP LEGS WATER HEATER 4) SECURE GAS LINE MECH ROOM 5) SEAL MECH ROOM LID 6) INSTALL VACUUM BREAKER HOSE BIBS 7) POST ADDRESS 8) GARAGE SERVICE DOOR MUS SELF LATCH 9) GARAGE OUTLET MUST BE GFI PROTECTED 10) COMPLETE WASH BASIN LAUNDRY 11) BEDROOM 3 NORTH OUTLET TESTS ? POLARITY 12) KITCHEN CIRCUITS DO NOT TEST GFI 13) MASTER BEDROOM OUTLETS NOT ARC FAULT PROTECTED 14) BEDROOM OUTLETS 2 NOT ARC FAULT PROTECTED |