Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T04CM01339

Parcel: 140293120


Addresses:

6122 S EARP WASH LN


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM01339

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/16/2004 FRAMING Approved IVRS - Inspection :*
06/15/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAIL PROTECT PLUMBING WITHIN 1 1/2" FROM EDGE OF STUD 2) FHA STRAP DOUBLE TOP PLATE MISSING NAILS AND WRONG NAILS BEING USED 3) OVERSPAN WEST WALL 4) PROVIDE DETAIL FOR CHICAGO LOOP IN KITCHEN 5) NAIL PROTECT ELECTRIC WITHIN 1 1/4 FROM EDGE OF STUD 6) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FROM AND INTO ATTIC 7) STOPPED INSPECTION. HAVE TRADES WALK HOUSE BEFORE RECALL