Permit: T04CM01318

Parcel: 140323470

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T04CM01318

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
06/03/2004 FRAMING Approved IVRS - Inspection :*
06/02/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) FRAMING WILL BE APPROVED WHEN LATH IS COMPLETE 2) REMOVE SCREEN FROM DRYER VENT 3) SEAL UNDER TUB DRAINS FROM 1ST TO 2ND FLOOR
06/01/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) DWV'S AND WATER LINES OK 2) GAS TEST AT 7 PSI, 10 PSI MINIMUM REQUIRED 3) REMOVE SCREEN FROM DRYER VENT 4) SEAL ALL PENETRATIONS FROM 1ST TO 2ND FLOOR AND INTO ATTIC SPACE 5) PROVIDE POSITIVE PITCH FOR WASHER DRAIN PIPE 6) NAIL PROTECT ABS AT MASTER BATH 7) SECURE ABS AT WATER HEATER AREA 8) MOVE ELECTRIC WIRES AWAY FROM GUSSETT PLATES 9) NAIL PROTECT WATER HEATER COPPER LINES
05/28/2004 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NAIL PROTECT WATER LINE IN GARAGE 2) ANCHOR BOLTS LOOSE THROUGHOUT 3) SHIM HEADERS 4) NO TEST ON DWV'S 5) MOVE ELECTRICAL WIRES AWAY FROM GUSSET PLATES 6) NAIL PROTECT PLUMBING KITCHEN 7) CRIPPLES AT KITCHEN WINDOW ? NO BEARING ON BOTTOM PLATE 8) NOT COMPLETE ENOUGH TO INSPECT 9) STOPPED INSPECTION HAVE TRADES WALK HOUSE BEFORE RECALL