Permit: T04CM01306

Parcel: 138133320

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/24/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/05/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*/ 1) NO LADDER ACCESS TO ROOF. YOUMUST APPROVED OSHA APPROVED LADDER ACCESS FOR ROOF INSPECTION. NEXT FAILURE WILL BE CHARGED A REINSPECTION FEE 2) NO CITY APPROVED TRUSS DRAWINGS ON SITE 3) PLAN CALLS FOR SIMPSON STHD8 HOLDOWNS METAL PRODUCTS USED PROVIDE APPROVED PLAN REVISION 4) NEED ROOF AND FLOOR TRUSS LAYOUT PLAN 5) GARAGE JAMBS REQUIRE 3 2 X 6 KING STUDS 6) GABLE END TRUSSES NOT CLIPPED PER 1/SD3 7) NW HOLDOWN NOT ON FULL LENGTH DOUBLE KING STUDS 8) CLIP KING STUDS 9) CLIP EVERY OTHER STUD 10) TWB'S REQUIRE 2 16D NAILS AT ENDS 11) 10/SD4 NOT COMPLIED WITH 12) STOPPED INSPECTION