Permit: T04CM01283

Parcel: 113070470


Addresses:

2933 N CAMPBELL AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T04CM01283

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
05/24/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ WTR HTR INSTALLED OK. OK TO COVER ALL AREAS.
05/18/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) OK TO COVER BATHROOM WALL. 2) SEE 511.2 94 UPC LOCATION OF WTR HTR.
05/17/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/ 1) HCS TIE-IN TO 4" CLAY 2 PLACES OK. OK TO COVER. 2) OK TO COVER WALL AT 2 SINKS. 3) A TRAP ARM MAY NOT CHANGE SIZE.
05/14/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*/ 1) PLBR: A TRAP ARM MAY NOT CHANGE SIZE. A TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. A TRAP MAY ONLY BE ONE SIZE LARGER THAN THE TAILPEICE TO WHICH IT IS CONNECTED. 2) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVELENT.