Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T04CM01283
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2004 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :*/ WTR HTR INSTALLED OK. OK TO COVER ALL AREAS. | |
| 05/18/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) OK TO COVER BATHROOM WALL. 2) SEE 511.2 94 UPC LOCATION OF WTR HTR. | |
| 05/17/2004 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :*/ 1) HCS TIE-IN TO 4" CLAY 2 PLACES OK. OK TO COVER. 2) OK TO COVER WALL AT 2 SINKS. 3) A TRAP ARM MAY NOT CHANGE SIZE. | |
| 05/14/2004 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :*/ 1) PLBR: A TRAP ARM MAY NOT CHANGE SIZE. A TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. A TRAP MAY ONLY BE ONE SIZE LARGER THAN THE TAILPEICE TO WHICH IT IS CONNECTED. 2) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVELENT. |