Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/24/2004 |
PLUMBING - INTERMEDIATE |
|
Approved |
IVRS - Inspection :*/ WTR HTR INSTALLED OK. OK TO COVER ALL AREAS. |
| 05/18/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ 1) OK TO COVER BATHROOM WALL. 2) SEE 511.2 94 UPC LOCATION OF WTR HTR. |
| 05/17/2004 |
PLUMBING - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection :*/ 1) HCS TIE-IN TO 4" CLAY 2 PLACES OK. OK TO COVER. 2) OK TO COVER WALL AT 2 SINKS. 3) A TRAP ARM MAY NOT CHANGE SIZE. |
| 05/14/2004 |
PLUMBING - INTERMEDIATE |
|
Not ready for Inspection |
IVRS - Inspection :*/ 1) PLBR: A TRAP ARM MAY NOT CHANGE SIZE. A TRAP IS TO BE THE SAME SIZE AS THE TRAP ARM TO WHICH IT IS CONNECTED. A TRAP MAY ONLY BE ONE SIZE LARGER THAN THE TAILPEICE TO WHICH IT IS CONNECTED. 2) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVELENT. |